The industry standard for the design and installation of automatic fire sprinkler systems. NFPA 13e, outlines various design methodologies, installation practices, and component selections aimed at mitigating fire-related fatalities and minimizing property damage.
Benefits of NFPA 13e
This edition of NFPA 13A has been updated for the first time since 2014, providing essential information and procedures for fire operations in settings equipped with active sprinkles and standpipes. All referenced materials have undergone thorough review and updates throughout the document.
Revised provisions aimed at ensuring consistency between NFPA 13E and other NFPA publications.
Reorganized chapters designed to enhance usability and assist users in comprehending the recommendations more effectively.
Added explanations regarding the maintenance of sprinkler heads for fire investigation purposes after their activation during emergencies, along with clarifications on the inspection process and the re-commissioning of sprinkler heads by qualified personnel.
New content detailing how museums and libraries should prepare for or respond to sprinkler activations, emphasizes the need for users to be aware of these specific scenarios within their jurisdictions.
Clarification that pressure adjustments are necessary when hose connections are situated below grade.
Details of the Book
Book Title: Recommended Practice for Fire Department Operations in Properties Protected by Sprinkler and Standpipe Systems
Publisher: National Fire Protection Association
Revised Edition: 2020
Language: English
SKU: 13E20PDF
ISBN- 10 : 1455924851 ‎
ISBN- 13 : 978-1455924851‎
FAQs
Q1. Are sprinklers required within furniture?
A1. No. Sprinklers are required within all permanent spaces of the structure, such as closets, in accordance with Movable furniture items, such as desks, dressers, and wardrobes, do not require sprinklers within them even when they are affixed to the permanent structure of the building.
Q2. If there are no hose connections inside a building sprinkled to comply with NFPA 13, willDoes the water demand need to include a hose stream allowance?
A2. Yes. An outside hose stream demand would be required in accordance.
(Note that the table specifies an option for 0, 50, or 100 gpm for inside hose demand.
Regardless of the inside hose demand, the total combined inside and outside hose demand.)
Q3. Can plastic pipe be used on a sprinkler system complying with NFPA 13e?
A3. The use of nonmetallic pipe that has been specifically listed for fire protection use. This pipe must be installed in accordance with its listing limitations, including
installation instructions.
Q4. What is a Standpipe System?
A4. Standpipe systems, which are essentially an expansion of the fire hydrant system, are a network of pipes that link a water supply to hose connectors. They are intended to give building residents or the fire department access to a pre-piped water system. Standpipe systems are intended to supply hose lines in key inside locations of buildings or other structures with water for fire prevention.
Q5. What is a standpipe for fire protection?
A5. In order to extinguish a fire and protect a building or structure, as well as its contents and its occupants, a standpipe is defined by the NFPA as an “arrangement of piping, valves, hose connections, and associated equipment installed in a building or structure, with the hose connections located in such a manner that water can be discharged in streams or spray patterns through attached hose and nozzles.”
In a nutshell, standpipe systems are a system of pipes that are fed by a water supply and have many water outputs inside a building. In essence, these are interior fire hydrants that provide water for fighting fires to residents, firemen, or both. Additionally, they have made it possible to construct and utilize towering buildings safely, much like the elevator brake.